ESTIMATED RESULT
Example 2×4 wood-framed wall Effective whole-assembly R-value R-11.81
Framing path R-value R-6.3
Cavity path R-value R-16
Continuous R-value R-2
Reduction caused by framing 26.14%
Effective RSI 2.08
Effective U-value 0.0846 Btu/(h·ft²·°F) 0.4806 W/(m²·K) Path comparison Effective assembly R-11.81
Wall assembly — interior to exterior Interior air film — Wall heat flow horizontal continuous · R-0.68 Gypsum board — Generic continuous · R-0.44 · 0.5 in ROCKWOOL Comfortbatt — Wood stud R14; 3.5 in cavity · R-14 · 3.5 in Wood structural framing — Spruce-pine-fir framing · R-4.31 · 3.5 in Oriented strand board — Generic continuous · R-0.71 · 0.5 in Exterior air film — Ceilings, floors and walls; winter wind 6.7 m/s continuous · R-0.17 This calculator provides a simplified estimate of effective thermal resistance using parallel heat-flow paths. Actual performance may also be affected by corners, headers, rim joists, windows, doors, fasteners, balconies, shelf angles, installation quality, and other thermal bridges. Confirm project requirements through appropriate energy modelling, code review, or professional analysis.